Hydrophilic Aluminium finstock is widely used in household colding equipment and vehicle air conditioner etc. As using spaness high-precise punch,our company adjusts the alloy and develop DS-1,DS-2,DS-3, whose performance targets grow up to the International advanced level. And our products are popular among many countries.
For main products here, the Alloy, Temper, Specification, Room temperature dynamics shall be according with the following table.
|
Alloy
|
Temper
|
Tensile
|
Extension
|
Erichson
|
Specification (mm)
|
|
(σb, Mpa)
|
δ% (50mm)
|
( mm )
|
Gauge
|
Width
|
ID
|
OD
|
|
1100
|
O
|
80-110
|
≥18
|
≥6.2
|
0.10-0.20
|
50-1070
|
75
|
≤800
|
|
1200
|
H22
|
95-135
|
≥15
|
≥5.5
|
150
|
|
DS-1
|
H24
|
125-145
|
≥13
|
≥5.0
|
200
|
|
1030B
|
H26
|
135-165
|
≥8
|
≥4.5
|
300
|
|
8011
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DS-2
|
H26
|
130-150
|
≥10
|
≥4.0
|
0.10-0.20
|
|
|
|
|
The hydrophilic coating ,as we all know ,has many merits,such as high corrosion resistance,no white powder,no pollution,without water bridge,radiating rapidly,high heat exchange effciency,reducing windage,conserving energy,and so on. And the main properties of our coating obey the following table.
|
Item
|
Index
|
|
Film gauge
|
2.0g/m2-3.0g/m2(two sides)
|
|
Adherence
|
Erichson test : no flaking
|
|
Primary hydrophile
|
The contact angle ≤10°
|
|
Corrosion resistance
|
Salt mist test : A
|
|
Heat resistance
|
200℃±5℃,keep 5 min,no clour change
|
|
Anti violate oil
|
soak in volatile oil for 24 hours,
|
|
no blisters on the coating film.
|
|
Odour
|
Free of odour.
|
|
The Corrosion resistance,Heat resistance & Anti violate oil shall
|
|
be checked according with the user's demands.
|
|